Nitrogen Leak Test Kit with Leaktronic 4 (Small Bottles)
This handy kit is designed for use with the small disposable nitrogen gas bottles and comes with the regulator to suite.
The use of dry Oxygen Free Nitrogen (OFN) is a long established means of pressure testing air conditioning and refrigeration systems. A drop in pressure on a test gauge indicates that there is a leak. The point of leakage can then
be found by using a leak spray, such as Spray Test (AC2172), or with an ultrasonic tester.
Nitro Traceâ„¢ gas, a combination of OFN with Hydrogen. Hydrogen has the smallest atom of all gases, and
will leak through the tiniest of leak sources, and as it can be detected using electronic hydrogen sensing technology, the leak location can be pin-pointed with Leaktronic-3 detector. (BLNTLO). Leak spray may be also used for added assurance of the leak source. (AC2172)
Contains:
N2 Regulator
2 Metre Hose
R134a coupler& R1234yf Coupler
N2 test unit with gauge & hose
Small Disposable Gas Bottle
All in a professional Aluminium Case
AC2314B with the addition of AC2686
LeaktronicTM 4
The above kit has automotive couplers for
both R1234yf and R134a
| Weight | 5.480000 |
|---|